AN6-S130
Damping coating for buildings and equipment
Damping
For industrial buildings and machinery: reduces vibration noise from metal roofing, ducts and structural members.
Source
AN6-S130 TDS v260112

Typical uses
- Rain impact noise control on metal roofing
- Vibration control of HVAC ducts and steel structures
- Machine enclosures, air compressors and generating equipment
Technical data
- System
- Modified water-based resin with functional fillers
- Wet density
- approx. 1.2 ± 0.1 g/cm³
- Dry density
- approx. 1.0 ± 0.1 g/cm³
- Solids by weight
- approx. 74 ± 2%
- Colour
- brown
- pH
- approx. 8–9
- Usage per 1 mm dry film
- approx. 1.2–1.4 kg/m² (wet)
- Composite loss factor
- 0.15 (test standard reference DIN EN ISO 6721-3)
- Thermal conductivity
- approx. 0.8 W/mK
- Thickness per pass
- up to 5 mm wet in one pass, approx. 4–4.5 mm when dry
- Application temperature
- not below 15 °C recommended
- Drying
- at 20 °C, 55% humidity and about 5 mm dry film, full drying takes 12–18 hours; raising to 50 °C takes about 2–4 hours (surface air speed below 5 m/s)
- Storage
- at least nine months in sealed original packaging; keep dry and cool, protect from frost
- Packaging
- 25 kg pails; 250 kg steel drums (with liner bag); 1200 kg bulk bags (with liner bag)
Application notes
- First confirm structural resonance, the main noise source and the environmental conditions, then assess the material configuration.
- The substrate must be clean and free of oil; run compatibility tests for each primer and metal surface.
- Design and application should avoid standing water and keep ventilation available for drying.