AI translation, not reviewed by a native speaker. Chinese version

AN2-701

AN2-701 Water-based damping coating

Damping

AN2-701 is a water-based damping coating applied to metal panels to suppress vibration noise. Substrates listed in our data include steel with anti-corrosion primer, galvanised steel, anodised aluminium and coil steel. At 20 °C, 55% RH and approx. 5 mm dry film, full drying takes 12–18 hours.

This page is archived material for reference only; contact Tech to confirm

Typical uses

  • Sound deadening in vehicles, trains, ships, box structures and similar equipment
  • Extended uses such as incinerators, elevators, ventilation ducts and power stations
  • Fields that need lasting waterproofing or other performance

Technical data

Viscosity
thixotropic fluid
Wet density
approx. 1.4 ± 0.1 g/cm³
Dry density
approx. 1.2 ± 0.1 g/cm³
Solids by weight
approx. 74 ± 2%
Colour
cream-yellow or black, or to customer request
pH
approx. 8–9
Usage per 1 mm dry film
approx. 1.4–1.8 kg/m² (wet); approx. 1.1–1.2 L/m² (wet)
Composite loss factor
0.2 (test standard reference DIN EN ISO 6721-3)
Thermal conductivity
approx. 0.2 W/mK
Thickness per pass
up to 5 mm wet in one pass, approx. 4–4.5 mm when dry
Application temperature
not below 15 °C recommended
Drying
at 20 °C, 55% humidity and about 5 mm dry film, full drying takes 12–18 hours; raising to 50 °C takes about 2–4 hours (surface air speed below 5 m/s)
Storage
at least nine months in sealed original packaging; keep dry and cool, protect from frost
Packaging
25 kg pails; 250 kg steel drums (with liner bag); 1200 kg bulk bags (with liner bag)

Application notes

  • Steel with a rust-inhibiting primer, galvanised steel, anodised aluminium, coil steel and similar; remove dust, oil and grease from the substrate and test compatibility before use.
  • Use airless equipment with a pump ratio of at least 60:1, air-assisted equipment with a 12:1 pump ratio, or screw-pump equipment with 3–4 bar input pressure; manual spraying equipment such as Spatula or Mortar types can also be used.
  • During application keep the coating surface even with no missed areas and use clean equipment where possible; a dried coating can be overcoated with other commercial coatings (one- or two-component, with or without solvent), and compatibility should be tested before application.
  • On train bodies and containers make sure the floor has drain holes so that a wetted coating can dry.
  • Clean with water promptly after application, adding household cleaner if needed. See the product MSDS for safety and disposal information.

Questions about products or applications?

No overseas samples