AI translation, not reviewed by a native speaker. Chinese version

AN2-CA

Sound-deadening coating

Damping

A sound-insulating and sound-deadening material based on an acrylic water-based emulsion. It suits conventional spraying and is aimed at walls, ceilings and pipework in civil buildings.

This page is archived material for reference only; contact Tech to confirm

Typical uses

  • Inner surfaces of exterior walls, walls of plant rooms or garages, and sound barriers around outdoor working equipment
  • Bathroom drain pipes, drainage pipes and cement floors between storeys
  • Ceilings of simple workshops and plants
  • Sprayed onto existing boards to make prefabricated boards that reinforce sound insulation in particular situations

Technical data

System
Acrylic water-based emulsion
Viscosity
thixotropic fluid
Wet density
approx. 1.4 ± 0.1 g/cm³
Dry density
approx. 1.2 ± 0.1 g/cm³
Solids by weight
approx. 74 ± 2%
Colour
cream-yellow or black, or to customer request
pH
approx. 8–9
Usage per 1 mm dry film
approx. 1.4–1.8 kg/m² (wet); approx. 1.1–1.2 L/m² (wet)
Composite loss factor
0.2 (test standard reference DIN EN ISO 6721-3)
Thermal conductivity
approx. 0.2 W/mK
Thickness per pass
up to 5 mm wet in one pass, approx. 4–4.5 mm when dry
Application temperature
not below 15 °C recommended
Drying
at 20 °C, 55% humidity and about 5 mm dry film, full drying takes 12–18 hours; raising to 50 °C takes about 2–4 hours (surface air speed below 5 m/s)
Storage
at least nine months in sealed original packaging; keep dry and cool, protect from frost
Packaging
25 kg pails; 250 kg steel drums (with liner bag); 1200 kg bulk bags (with liner bag)

Application notes

  • Walls and ceilings of buildings need only simple protective treatment; during airless spraying the spraying itself removes dust from adjacent surfaces.
  • Use airless equipment with a pump ratio of at least 60:1, air-assisted equipment with a 12:1 pump ratio, or screw-pump equipment with 3–4 bar input pressure; manual spraying equipment such as Spatula or Mortar types can also be used.
  • During application keep the coating surface even with no missed areas and use clean equipment where possible; a dried coating can be overcoated with other commercial coatings (one- or two-component, with or without solvent), and compatibility should be tested before application.
  • Clean with water promptly after application, adding household cleaner if needed. See the product MSDS for safety and disposal information.

Questions about products or applications?